Turkish Journal of Chemistry
DOI
-
Abstract
The voltammetric behaviour of cysteine was investigated in the presence of Cu(II) ions at a rotating glassy carbon electrode (RGCE). Two reduction peaks related to the successive reduction of the cysteine complexes of Cu(II) and Cu(I) ions were observed at --0.30 and --0.60 V vs. SCE respectively. These peaks were increased upon the addition of cysteine into a pH 9.20 borate buffer solution containing 0.1 M KNO_{3} and 1.0 x 10^{-5} M Cu(II) ions. The calibration curve was linear in the concentration range of 5.0 x 10^{-10}- 2.0 x 10^{-8} M for cysteine by utilising the peak current at --0.6 V vs. SCE. In the flow technique, 50 \mu L portions of off-line prepared mixtures of 1.0 x 10^{-5} M Cu(II) and varying concentrations of cysteine were injected into the carrier solution of pH 9.20 borate buffer containing 0.1 M KNO_{3} flowing through 25 cm transmission tubing (i.d. 0.75 mm) at a rate of 1.5 mL/min. The signals were monitored at -- 0.60 V vs. SCE. The calibration graph was found to be linear in the concentration range 1.0 x 10^{-9} -- 1.0 x 10^{-7} M with a relative standard deviation of 1.0\% (n = 5) for 5.0 x 10^{-8} M cysteine. The detection limit was calculated as 5 x 10^{-10} M for S/N = 3 ratio.
First Page
513
Last Page
520
Recommended Citation
DURSUN, ZEKERYA; ŞAHBAZ, İLYAS; ERTAŞ, F. NİL; and NİŞLİ, GÜREL (2003) "Voltammetric and Flow Injection Amperometric Determination of Cysteine at a Glassy Carbon Electrode in the Presence of Copper(II) Ions," Turkish Journal of Chemistry: Vol. 27: No. 4, Article 12. Available at: https://journals.tubitak.gov.tr/chem/vol27/iss4/12