Turkish Journal of Chemistry

Abstract

The flow injection speciation of manganese in aqueous solution using a spectrophotometry method of detection is presented. Manganese (VII) can be determined spectrophotometrically at 308 nm after the reaction with Sym-diphenycarbazide in buffered at pH = 3.05 with phosphate. Under the optimized conditions, total manganese concentration can also be determined after oxidation of Mn^{2+} to MnO_{4}^{-} and then Mn^{2+} concentration can be calculated from the difference. The linear range of determination is 0.047-4.50 mg/l with a 3\sigma detection limit of 31 \mu g/l. The proposed method is applied to the determination of MnO_{4}^{-} and Mn^{2+} in effluent streams and foods with a relative standard deviation better than 1.85%. A sampling frequency of up to 24 h^{-1} can be achieved. Interfering ions can be removed by an ion-exchange column built into the flow injection system.

DOI

-

Keywords

Flow-injection, Speciation, Manganese, Effluent streams, Foods

First Page

227

Last Page

234